What is

S-Keeper 7 armadio interoWhat is S-Keeper 7™?

S-Keeper 7™ is a Continuous Emissions Monitoring System CEMS Type Approved for marine application fully engineered, integrated and validated in accordance with the applicable Directives. S-Keeper 7™ is made in Italy by Tecnova HT.

S-Keeper 7™ has been found to comply with the applicable requirements for SO2 and CO2 analyzer specified in Chapter 6 of Resolution MEPC.259(68) “2015 Guidelines for exhaust gas cleaning systems”  therefore it is ” Scrubber Ready “. Now.

S-Keeper 7™ is  obviously  already in compliance with:

  • MARPOL Annex VI Reg. 13 & 14
  • MEPC Circ. 471, 177(58), 259(68)
  • IEC 60092-504
  • Regulation (EU) 2015/757

S-Keeper 7™ is fully tailored to the Shipowner’s requirements with particular focus on CaPex & OpEx balance.

S-Keeper 7™ could be also integrated with a modern PEM Propulsion Efficiency Monitor, thus encompassing metered Fuel Consumption, Fuel Oil Viscosity, Thrust and Torque measuring Systems.

Thanks to the specific engineering of this modular system, the S-Keeper 7™ installation is able to withstand the toughest marine environment.

On-board maintenance is easy even for an unskilled operator, while the SPMP Spare Parts Management Program ensures the traceability of every single component and its availability on the ship’s course.

S-Keeper 7™ Main features

In accordance with MARPOL Annex VI Reg.13 & MEPC 177(58), 259(68)

  • calculation of NOx g/kWh vs Tier I, Tier II, Tier III limits
  • monthly NOx compliance test report

In accordance with MARPOL Annex VI Reg.14 & MEPC 177(58), 259(68)

  • calculation SO2/CO2 ratio
  • calculation of Fuel Oil Sulphur content (% wt/wt) vs Reg.14 limits

In accordance with MEPC 177(58),  & MEPC 259(68)

  • HC total Hydrocarbons content (ppm or g/kWh) is measured

In accordance with Regulation (EU) 2015/757  (aka MRV plan)

  • CO2 emissions for each ship on a per-voyage and an annual basis are monitored, reported & verificated

In accordance with NOx Technical Code, Appendix 3, par. 1.1

  • Extraction Method is implemented

S-Keeper 7_MARPOL ANNEX VI_TECNOVA HT

 

Reports in accordance with ISO 14001 of totalized mass NOx / SOx / CO2 emissions (kg/tonne)
Reports in accordance with MEPC Circ. 471 of CO2 Emission Index (g CO2 / tonne n.m.)
Combustion Efficiency monitoring by CO2/(CO2+CO) ratio

Types EASY-N, LITE-N, LITE  are specifically designed for LNG Powered Ships thanks to “CH4 slipstream” management

O2 (%) & Particulate (mg/m3 or g/kWh) analysis as additional options

Ship Multiple Stacks management available

S-Keeper 7™ Selection Table

EGCS CEMS

Few Examples:

  1. For Scrubber cleaned gas/EGCS : EASY-S
  2. Downstream SCR Selective Catalytic Reduction : EASY-N
  3. SCR & Scrubber equipment: EASY
  4. LNG Powered Ship: LITE…

S-Keeper 7™ Technical Specifications

Analyzed components measuring method

NOx, SO2, CH4, CO, CO2: NDIR (NO with NO2 to NO converter)

analytical options avalaible:

HC: H-FID heated flame ionization detector

O2: Zirconium Oxide

Particulate: Inductive Electrification

Multiple Stack Management

Up to 6 funnels could be analyzed with 1 single S-Keeper 7™

Auxiliary inputs

Engine speed, Torque, Thrust, Fuel flow, Ambient temperature, Pressure & Humidity sensors as indicated in “NOX Technical Code 2008”, EGCS Exhaust Gas Cleaning System ( Scrubber ) operative parameters as required in “MEPC.259(68)-2015 Guidelines for Exhaust Gas Cleaning Systems”, Ship GPS Global Positioning System data.

Software

Windows®-based Emissions Reporting software

Easy self-explanatory graphical interface with Process Flow Diagram and real-time parameters

Multilevel Password Protection and Data Encryption to ensure safest tamperproof procedure I/O

Connections

1 x Ethernet RJ45, 1 x RS-485, 1 x SPDT contact


S-Keeper 7™ Scope of Supply

  • Qty#1 Integrated Cabinet
  • Qty#1 Sample probe & tube (up to 6 for MSM)
  • Qty#1 Sample line (up to 6 for MSM)
  • Qty#1 Bottles set (according to analyzed components)


S-Keeper 7™ Analytical Options avalaible upon request

  • Qty#1 Oxygen Analyser
  • Qty#1 Hydrocarbons Analyser
  • Qty#1 Particulate Analyzer
  • Qty#1 Multiple Sample Controller for MSM
  • Qty#1 Redundant Analyser PLUS option

S-Keeper 7™ Sample conditioning system

In accordance with “NOX Technical Code 2008” with system condition monitoring and maintenance indicators.

Sample probe technical specifications

Operative Conditions: max. 200 kPa abs, 180°C

Filter element in Bonded Silicon Carbide (CSi), wetted parts in SS316Ti, CSi, Viton®

Flanged Process Connection: DN 65 PN 6 DIN 2573

Housing: SS304, IP43 rating

Sample line technical specifications

Operative Temperature 190°C/Max 210°C/Peak 250°C

Maximum Operating Pressure 2.8 barg@200°C

Wetted parts PTFE material, External insulation Fiberglass

External diameter 43 mm, End Caps diameters 48 mm

Minimum Allowable Bending Radius 200 mm


S-Keeper 7™ Ambient Conditions Limits

Main Integrated Cabinet: Ambient Temperature +5 / +55°C; 95% RH Max

Sample Probe: Ambient Temperature +5 / +55°C; 95% RH Max

Particulate Analyzer (option): Ambient Temperature +5 / +55°C; 95% RH Max


S-Keeper 7™ Utilities Consumption

Power supply: 230 VAC @50/60 Hz

Maximum power consumption (Full model): 4.8 KVA Max

Calibration gas bottle / each parameter: 1 bottle 110 L @ 20°C / 1 operative year approx

Demi water (only Lite-s, Lite, Full models). 1 canister of 5 Liters / 3 operative months approx.


S-Keeper 7™ Dimensions & Weight

Main integrated cabinet: 1050 x 1990 x 800 mm (WxHxD), 550 kg

Sample probe: Housing 251 x 297 x 168 mm (WxHxD), 9 kg, Length TBD

Sample line: Length TBD , 0.9 Kg/m

Calibration bottle: 360 (H) x 90 mm (DN), 1.7 L, 1.1 kg each

Oxygen analyzer (optional): Integrated in main cabinet

Particulate analyzer (optional): Flanged housing 342 (L) x 74 mm (DN), 1.7 kg, insertion length TBD

SK7-Dis.Tecnico